Hand-held Multi-Gas Analyzer

Capnoxi plus AG 
Handheld EtCO2 monitor Detecting gas: EtCO2, FiCO2, RR,EtN2O, FiN2O, EtAA, FiAA. High Precision.

anesthesia agent analyzer used to measure EtCO2, FiCO2, RR, EtN2O, FiN2O, EtAA, FiAA.

Price : 1553 USD
Buy 05:  -  05%  OFF
Buy 07:   - 10%  OFF
Buy 10:   - 12% OFF


Product Features

Monitoring SpO2 pulse rate ETCO2 and respiratory rate;
Update 255-hour historical data replay on PC through USB
Equip Spo2 and Respiratory Status Analysis Software comprehensive data analysis
Suitable for clinical and emergency circumstance
SpO2 SpO2+CO2 selectable
 
Software Function
Professional Data Analysis Software for CO2 Monitoring
Connecting the palm monitor to PC through USB
Storing Unlimited patient’s data
Displaying ETCO2,SPO2 Trends Table
Controlling PC printer outputting trend graph trend table report
Recording and storage object’s respiration details in clinical
 

Inside Pump Made by


Product Specifications

Main Unit’s Environment Requirement
 
Working:          Temperature: 5℃~50℃; 
                        Relative humidity: 0~95%;          
                        Atmosphere Pressure: 70.0KPa~106.0KPa
Storage:          Temperature: 0℃~70℃; 
                       Relative humidity: 0~95%;
                       Atmosphere Pressure: 22.0KPa~120.0KPa 
 
 
LED                             
 
Patient Alarm Indicator: Two colors: Yellow and Red
Sound Indicator           
Loudspeaker:         Play alarm voices
Interfaces                     
 
Power:                    12VDC power socket x 1
 
USB:                       MINI USB socket x 1
 
Measurement Specification
 
Principle:                 NDIR single beam optics
Sampling Rate:       90mL/min ±10mL/min
Initialization Time:   Waveform displaying in 20 seconds
 
Range                           
 
CO2:                0~99 mmHg 0~13 %
N2O:                0~100 VOL%
ISO:                 0~6VOL%
ENF:                0~6VOL%
SEV:                0~8VOL%
RR:                 2~150 bpm
 
Resolution                   
 
CO2:               0~40 mmHg    ±2 mmHg
                       40 ~99 mmHg  ±5% of reading
 
N2O:               0~100VOL% 
                       ±(2.0 vol% +5% of reading)
 
ISO:               0~6VOL%   
                      ±(0.3 vol% +2% of reading)
 
ENF:               0~6VOL%   
                       ±(0.3 vol% +2% of reading)
 
SEV:               0~8VOL%   
                       ±(0.3 vol% +2% of reading)
 
RR:                ±1 bpm
Apnea Alarm Time:    20~60s
 
 
MAC value defines 
 
  • 1.0MAC: under an atmospheric pressure condition give a person or animal skin stimulation 50% of people or animals not body dynamic response or escape reflection occurs the inhalation anesthetics in alveolar concentration. 
  • To achieve 95% of people don’t respond to stimuli the MAC value should reach to 1.3. 
  • When MAC value is 0.4,most patients will wake up.
 
Anesthetic agents
 
Enflurane:         1.68
Isoflurane:         1.16
Sevoflurane:     1.71
Halothane:        0.75
N2O:                 100%
Notice                Desflurane’s MAC1.0 values differ with age
Age:                  18-30   MAC 1.0  7.25%
Age:                   31-65   MAC 1.0  6.0%
 
 
 
Power Specification
 
Input Voltage:       12V DC
Input Current:       2.0 A    
 
Physical Specification
 
Main Unit
Weight:               0.65Kg
Dimension:         192mm x 106mm x 44mm
 
Hardware Specification
 
TFT Screen
Type:                   Colorful TFT LCD
Dimension:          5.0 inch
 
Battery                          
Quantity:             4
Model:                Rechargeable lithium battery
Voltage:              3.7 V
Capacity:            2200mAh
Working time:     10 hours
Recharging time: 4 Hours
 

 


Related Accessories