MD908C

Patient monitor 12inch TFT. Automatic temperature drift treatment of NIBP measuring patented technology;Friendly and configurable user interface;Powerful data review:Maximum 720-hour graphic and tabular trends,
Up to10000 pieces of NIBP record storage,

Wired or wireless networkable with Central Monitoring System;On-line upgrading keeps you updated;


Price: 210 USD
Buy 25:   - 20% OFF

Product Features

High resolution 12” color TFT display
12 Channel waves.9 Parameters : ECG Resp NIBP SpO2 TEMP
Light weight compact and portable
Built-in rechargeable lithium battery 
Unique human voice alarm
Rich screen layouts: Standard Big font Trend table NIBP trend ECG full lead OxyCRG IoC Layout
Powerful storage: Maximum 720 Hour graphic and tabular trends of all
parameters up to 10000 NIBP review 200alarm review 2Hours of all waveforms
System software can be upgraded through network
Data and waveforms color be adjustable
Arrhythmia analysis and S-T segment analysis
Suitable for adult paediatric and neonatal patient




Options 
Invasive Blood Pressure (IBP)
Carbon dioxide (CO2) Module
Thermal Printer
Touch Screen


Product Specifications


ECG 
Lead Mode                   5 Leads ( R L F N C or RA LA LL RLV)
Lead selection              I II III avR avL avF V 
Waveform                     2 ch 
Lead mode                   3 Leads ( R L F or RA LA LL)
Lead selection              I II III 
Waveform                    1 ch 
Gain x2.5mm/mV x5.0mm/mV x10mm/mV x20mm/mV  auto 
HR and Alarm  
      Range 
      Adult                     15 ~ 300 bpm
      Neo/Ped               15 ~ 350 bpm
      Accuracy               ± 1% or ± 1bpmwhich great
      Resolution            1 bpm
     Sensitivity              > 200 (uV ) 
Differential Input Impedance  > 5 MΩ
CMRR
      Monitor                 > 105 dB 
     Operation              > 105 dB
     Diagnosis              > 85 dB
Electrode offset potential  ±300mV
Leakage Current       < 10 uA
baseline Recovery    < 3 S  After Defi.
ECG Signal Range     ±8 m V ( Vp-p ) 
Bandwidth    
     Surgery                 1 ~ 15 Hz
     Monitor                  0.5 ~ 35 Hz
     Diagnostic             0.05 ~ 100 Hz
Calibration Signal    1 (mV )  Accuracy :±5%  
ST Segment Monitoring Range   
Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting  
Type ASYSTOLE VFIB/VTAC COUPLET BIGEMINY TRIGEMINY R ON T VT>2 PVC TACHY BRADYMISSED BEATS PNP PNC 
    Alarm     Available
    Review    Available 

RESPARATION 
Method      Impedance between R-F(RA-LL)
Differential Input Impedance    >2.5 MΩ
Measuring Impedance Range:  0.3~5.0Ω
base line Impedance Range:    0 – 2.5  KΩ
Bandwidth     0.3 ~ 2.5 Hz
Resp. Rate 
Measuring and Alarm Range 
     Adult                0 ~ 120 rpm
     Neo/Ped          0 ~ 150 rpm 
Resolution                      1 rpm
Accuracy                      ±2 rpm 
Apean Alarm            10 ~ 40 S 

NIBP 
Method                Oscillometric
Mode        Manual Auto STAT
Measuring Interval in AUTO Mode 1 2 3 4 5 10 15 30 60 90 120 180 240480 (Min)
Measuring Period in STAT Mode 5 Min
Pulse Rate Range    40 ~ 240 bpm
Alarm Type            SYS DIA MEAN
Measuring and alarm range    
Adult Mode
             SYS   40 ~ 270 mmHg
             DIA    10 ~ 215 mmHg
             MEAN  20 ~ 235 mmHg 
Pediatric Mode
             SYS   40 ~ 200 mmHg
             DIA    10 ~ 150 mmHg 
             MEAN  20 ~ 165 mmHg
Neonatal Mode 
             SYS   40 ~ 135 mmHg
             DIA    10 ~ 100 mmHg
             MEAN   20 ~ 110 mmHg 
Resolution 
              Pressure    1mmHg
              Accuracy
              Pressure  
Maximum Mean error     ±5mmHg
Maximum Standard deviation  ±8mmHg 
Overpressure Protection
             Adult Mode        297±3 mmHg 
             Pediatric Mode  240±3 mmHg
             Neonatal Mode  147±3 mmHg 

SpO2 
Measuring Range          0 ~ 100 %
Alarm Range                 0 ~ 100 %
Resolution                     1 %
Accuracy                      70% ~ 100%  ±2 %
                                     0%  ~  69%  unspecified
Actualization interval   about 1 Sec.
Alarm Delay                  10 Sec. 
Pulse Rate 
Measuring and Alarm Range  0~254bpm
Resolution                        1bpm 
 Accuracy                         ±2bpm 

TEMPERATURE 
Channel      1
Measuring and Alarm Range  0 ~ 50  C
Resolution                          0.1~C
Accuracy                          ±0.1~C 
Actualization interval about 1 Sec.
Average Time Constant   < 10 Sec. 

IBP 
Label      ART PA CVP RAP LAP ICP P1 P2
Measuring and alarm range 
    ART                           0 ~ 300 mmHg
    PA                             -6 ~ 120 mmHg
    CVP/RAP/LAP/ICP  -10 ~ 40 mmHg
    P1/P2                       -10 ~ 300 mmHg     
Press Sensor 
Sensitivity                      5  uV/V/mmHg 
   Impedance                 300-3000Ω
   Resolution                    1 mmHg 
   Accuracy      ±2% or ±1mmHg which great about 1 Sec. 
 

ECG 
Lead Mode                   5 Leads ( R L F N C or RA LA LL RLV)
Lead selection              I II III avR avL avF V 
Waveform                     2 ch 
Lead mode                   3 Leads ( R L F or RA LA LL)
Lead selection              I II III 
Waveform                    1 ch 
Gain x2.5mm/mV x5.0mm/mV x10mm/mV x20mm/mV  auto 
HR and Alarm  
      Range 
      Adult                     15 ~ 300 bpm
      Neo/Ped               15 ~ 350 bpm
      Accuracy               ± 1% or ± 1bpmwhich great
      Resolution            1 bpm
     Sensitivity              > 200 (uV ) 
Differential Input Impedance  > 5 MΩ
CMRR
      Monitor                 > 105 dB 
     Operation              > 105 dB
     Diagnosis              > 85 dB
Electrode offset potential  ±300mV
Leakage Current       < 10 uA
baseline Recovery    < 3 S  After Defi.
ECG Signal Range     ±8 m V ( Vp-p ) 
Bandwidth    
     Surgery                 1 ~ 15 Hz
     Monitor                  0.5 ~ 35 Hz
     Diagnostic             0.05 ~ 100 Hz
Calibration Signal    1 (mV )  Accuracy :±5%  
ST Segment Monitoring Range   
Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting  
Type ASYSTOLE VFIB/VTAC COUPLET BIGEMINY TRIGEMINY R ON T VT>2 PVC TACHY BRADYMISSED BEATS PNP PNC 
    Alarm     Available
    Review    Available 

RESPARATION 
Method      Impedance between R-F(RA-LL)
Differential Input Impedance    >2.5 MΩ
Measuring Impedance Range:  0.3~5.0Ω
base line Impedance Range:    0 – 2.5  KΩ
Bandwidth     0.3 ~ 2.5 Hz
Resp. Rate 
Measuring and Alarm Range 
     Adult                0 ~ 120 rpm
     Neo/Ped          0 ~ 150 rpm 
Resolution                      1 rpm
Accuracy                      ±2 rpm 
Apean Alarm            10 ~ 40 S 

NIBP 
Method                Oscillometric
Mode        Manual Auto STAT
Measuring Interval in AUTO Mode 1 2 3 4 5 10 15 30 60 90 120 180 240480 (Min)
Measuring Period in STAT Mode 5 Min
Pulse Rate Range    40 ~ 240 bpm
Alarm Type            SYS DIA MEAN
Measuring and alarm range    
Adult Mode
             SYS   40 ~ 270 mmHg
             DIA    10 ~ 215 mmHg
             MEAN  20 ~ 235 mmHg 
Pediatric Mode
             SYS   40 ~ 200 mmHg
             DIA    10 ~ 150 mmHg 
             MEAN  20 ~ 165 mmHg
Neonatal Mode 
             SYS   40 ~ 135 mmHg
             DIA    10 ~ 100 mmHg
             MEAN   20 ~ 110 mmHg 
Resolution 
              Pressure    1mmHg
              Accuracy
              Pressure  
Maximum Mean error     ±5mmHg
Maximum Standard deviation  ±8mmHg 
Overpressure Protection
             Adult Mode        297±3 mmHg 
             Pediatric Mode  240±3 mmHg
             Neonatal Mode  147±3 mmHg 

SpO2 
Measuring Range          0 ~ 100 %
Alarm Range                 0 ~ 100 %
Resolution                     1 %
Accuracy                      70% ~ 100%  ±2 %
                                     0%  ~  69%  unspecified
Actualization interval   about 1 Sec.
Alarm Delay                  10 Sec. 
Pulse Rate 
Measuring and Alarm Range  0~254bpm
Resolution                        1bpm 
 Accuracy                         ±2bpm 

TEMPERATURE 
Channel      1
Measuring and Alarm Range  0 ~ 50  C
Resolution                          0.1~C
Accuracy                          ±0.1~C 
Actualization interval about 1 Sec.
Average Time Constant   < 10 Sec. 

IBP 
Label      ART PA CVP RAP LAP ICP P1 P2
Measuring and alarm range 
    ART                           0 ~ 300 mmHg
    PA                             -6 ~ 120 mmHg
    CVP/RAP/LAP/ICP  -10 ~ 40 mmHg
    P1/P2                       -10 ~ 300 mmHg     
Press Sensor 
Sensitivity                      5  uV/V/mmHg 
   Impedance                 300-3000Ω
   Resolution                    1 mmHg 
   Accuracy      ±2% or ±1mmHg which great about 1 Sec. 
 



Related Accessories

Standard:

ECG Cable (5 Leads) ...... 1Pcs
SpO2 Cable (Adult)  ........ 1Pcs
TEMP Probe (Adult)  ....... 1Pcs
NIBP Cuff (Adult)  ............ 1Pcs
NIBP Tube(150cm)  ......... 1Pcs
Ground Cable   ................ 1Pcs
Power Cable  ................... 1Pcs
Cleaning Cloth  ................ 1Pcs

Options:

ECG Cable (3 Leads)
ECG Alligator Clips (metal)
SpO2 Cable (Adult hard shell sensor)
SpO2 Cable (Adult Soft shell sensor) 
SpO2 Cable (Neonatal soft sensor) 
SpO2 Cable (Pediatric hard shell sensor) 
SpO2 Cable (Pediatric Soft shell sensor)
SpO2 Cable (Child finger clip)
SpO2 Cable (multi-site Y type)
SpO2 External Cable
NIBP Cuff (infant 8 - 14 cm 5/Bag)
NIBP Cuff (Child 13 - 20 cm 5/Bag)
NIBP Cuff (Small Adult 18 - 26 cm 5/Bag)
NIBP Cuff (Adult 26 - 35 cm 5/Bag)
NIBP Cuff (Adult Long 29 - 38 cm 5/Bag)
NIBP Cuff (Large Adult 32 - 42 cm 5/Bag)
NIBP Cuff (Large Adult Long 35 - 44 cm 5/Bag)
NIBP Cuff (Thigh 42 - 50 cm)
NIBP Tube 150cm
Paper Role
Thermal printer
Patient Monitor Wall mounts (3 Models)
Patient Monitor Trolley (5 Models)
EtCO2 Module
CO2 Sample Line
Nasal Tube
Water-trap Column
Airway Adapter
IBP Adapter (2-IBP)
IBP Reusable Interface Cable 
IBP Disposable Transducers