MD908s
patient monitor has a 12.1"color TFT screen.
Monitoring ECG, SP02, NIBP, RESP .2-TEMP. PR as standard parameters, and 2-IBP, ETC02 and thermal printer as options,
Price: 275 USD
Buy 30: - 21% OFF
Monitoring ECG, SP02, NIBP, RESP .2-TEMP. PR as standard parameters, and 2-IBP, ETC02 and thermal printer as options,
Price: 275 USD
Buy 30: - 21% OFF
Product Features
12.1'' TFT color LCD multi-language interface(Simplified Chinese Traditional Chinese English French German Turkish Spanish Portuguese Italian Dutch Romanian Russian Kazakh Polish Czech).
Fanless design quiet energy-saving and clean which reduces the possibility of cross-infection.
All-round monitor for adult pediatric and neonate.
With standard interface oxygen graph trend graph big character interface and view bed convenient to observe.
Finish all operations by keys and knobs.
Maximum 8-channel waveform synchronous display.
Display 7-lead ECG waveform on one screen cascade ECG waveform display
Adopt digital SpO2 technology anti-motion and anti-ambient light interference and measurement can be performed under the circumstance of weak filling.
Heart rate variability (HRV) analysis function
NIBP measurement mode: Manual/AUTO/STAT storage for 4800-group NIBP data.
Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
Drug concentration calculation and titration table functions.
One-touch printing of trend graph
Connect to Central Monitoring System by 3G Wi-Fi or wired mode.
AC/DC built-in rechargeable lithium battery achieve uninterrupted monitoring.
Anti-high frequency surgical unit defibrillation-proof (special leads are necessary).
Options
Invasive Blood Pressure (IBP)
Carbon dioxide (CO2) Module
Masimo SpO2 Module
Thermal Printer
Invasive Blood Pressure (IBP)
Carbon dioxide (CO2) Module
Masimo SpO2 Module
Thermal Printer
Product Specifications
ECG
Lead Mode 5 Leads ( R L F N C or RA LA LL RL V)
Lead selection I II III avR avL avF V
Waveform 2 ch
Lead mode 3 Leads ( R L F or RA LA LL)
Lead selection I II III
Waveform 1 ch
Gain ´2.5mm/mV ´5.0mm/mV ´10mm/mV ´20mm/mV
HR and Alarm
Range
Adult 30 ~ 300 bpm
Neo/Ped 30 ~ 350 bpm
Accuracy ±1% or ±1bpm which great
Resolution 1 bpm
Sensitivity > 200 uV P-P
Differential Input Impedance > 5 MΩ
CMRR
Monitor > 105 dB
Operation > 105 dB
Diagnosis > 85 dB
Electrode offset potential ±300mV
Leakage Current < 10 uA
baseline Recovery < 10 s After Defi.
ECG Signal Range ±8 mV (Vp-p)
Bandwidth
Surgery 1 ~ 15 Hz
Monitor 0.5 ~ 35 Hz
Diagnostic 0.05 ~ 100 Hz
Calibration Signal 1 mV (Vp-p) ±5% Accuracy
ST Segment Monitoring Range
Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting
Type ASYSTOLE VFIB/VTAC COUPLET BIGEMINY TRIGEMINY R ON T VT>2 PVC TACHY BRADY MISSED BEATS PNP PNC
Alarm Available
Review Available
Tall T-wave rejection capability 1.2mV
Heart rate averaging the average value of the latest 6 R-R intervals which have ignored the maximum and minimum
Updating rate of the display 1s
Heart rate meter accuracy and response to irregular rhythm:
Bigeminy ventricular 80bpm
Bigeminy ventricular alternative lente 57 or 63bpm
Bigeminy ventricular alternative rapid 122 or 123bpm
Systoles bidirectional 95bpm
Response time to heart rate meter to change in heart rate 80 to 120bpm
Average 3.7s
Range 3.2s ~ 4.1s 80 to 40bpm
Average 4.7s
NIBP
Method Oscillometric
Mode Manual Auto STAT
Measuring Interval in AUTO Mode 1 2 3 4 5 10 15 30 60 90120240480960Min
Measuring Period in STAT Mode 5 Min
Pulse Rate Range 40 ~ 240 bpm
Alarm Type SYS DIA MEAN
Measuring and alarm Range
Adult Mode
SYS 40 ~ 270 mmHg
DIA 10 ~ 215 mmHg
MEAN 20 ~ 235 mmHg
Pediatric Mode
SYS 40 ~ 200 mmHg
DIA 10 ~ 150 mmHg
MEAN 20 ~ 165 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Resolution
Pressure 1mmHg
Accuracy
Pressure
Maximum Mean error ±5mmHg
Maximum Standard deviation ±8mmHg
Overpressure Protection
Adult Mode 297±3 mmHg
Pediatric Mode 240±3 mmHg
Neonatal Mode 147±3 mmHg
TEMPERATURE
Channel 2
Measuring and Alarm Range 0 ~ 50 °C
Resolution 0.1°C
Accuracy ±0.1°C
Actualization interval about 1 Sec.
Average Time Constant < 10 Sec.
IBP (optional)
Channel 2
Label ART PA CVP RAP LAP ICP P1 P2
Measuring and alarm range
ART 0~300mmHg
PA -6~120mmHg
CVP/RAP/LAP/ICP -10~40mmHg
P1~P2 -10~300mmHg
Press Sensor
Sensitivity 5 uV/V/mmHg
Impedance 300-3000Ω
Resolution 1mmHg
Accuracy ±2% or 1mmHg which great
Actualization Interval about 1 Sec
Display
Device
12.1 in. Color TFT Made by Sharp Japan
Messages
7 Waveforms Maximum
1 Alarm LED ( Yellow/Red)
1 Power LED (Green)
1 Battery Charge LED ( Yellow)
3 Sound Mode corresponding Alarm Mode
Signal Interface
ECG Output BNC
Amplitude 1 V/mV
Accuracy < 5 %
Impedance 50 Ω
Signal Delay < 20 mS
Recall
Trend Recall
Short 1 hrs 1 Second Resolution
Long 72 hrs 1 Min. Resolution
Alarm Event Recall
71 alarm events of all parameters and 8/16/32seconds of corresponding waveform.
NIBP Measurement Recall
At least 400 NIBP measurement data.
Battery
Rechargeable 3.7 A/Hr 7.4V Li battery
Operating time under the normal use and full charge greater than 180minutes
Operating time after the first alarm of low battery will be about 5 minutes
Recorder (Option)
Record Width 48 mm
Paper Speed 25/50 mm/S
Trace 2
Size and Weight
Size Monitor 310 x 140 x 263 mm
Weight Monitor 3.8 kg
Lead Mode 5 Leads ( R L F N C or RA LA LL RL V)
Lead selection I II III avR avL avF V
Waveform 2 ch
Lead mode 3 Leads ( R L F or RA LA LL)
Lead selection I II III
Waveform 1 ch
Gain ´2.5mm/mV ´5.0mm/mV ´10mm/mV ´20mm/mV
HR and Alarm
Range
Adult 30 ~ 300 bpm
Neo/Ped 30 ~ 350 bpm
Accuracy ±1% or ±1bpm which great
Resolution 1 bpm
Sensitivity > 200 uV P-P
Differential Input Impedance > 5 MΩ
CMRR
Monitor > 105 dB
Operation > 105 dB
Diagnosis > 85 dB
Electrode offset potential ±300mV
Leakage Current < 10 uA
ba
ECG Signal Range ±8 mV (Vp-p)
Bandwidth
Surgery 1 ~ 15 Hz
Monitor 0.5 ~ 35 Hz
Diagnostic 0.05 ~ 100 Hz
Calibration Signal 1 mV (Vp-p) ±5% Accuracy
ST Segment Monitoring Range
Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting
Type ASYSTOLE VFIB/VTAC COUPLET BIGEMINY TRIGEMINY R ON T VT>2 PVC TACHY BRADY MISSED BEATS PNP PNC
Alarm Available
Review Available
Tall T-wave rejection capability 1.2mV
Heart rate averaging the average value of the latest 6 R-R intervals which have ignored the maximum and minimum
Updating rate of the display 1s
Heart rate meter accuracy and response to irregular rhythm:
Bigeminy ventricular 80bpm
Bigeminy ventricular alternative lente 57 or 63bpm
Bigeminy ventricular alternative rapid 122 or 123bpm
Systoles bidirectional 95bpm
Response time to heart rate meter to change in heart rate 80 to 120bpm
Average 3.7s
Range 3.2s ~ 4.1s 80 to 40bpm
Average 4.7s
NIBP
Method Oscillometric
Mode Manual Auto STAT
Measuring Interval in AUTO Mode 1 2 3 4 5 10 15 30 60 90120240480960Min
Measuring Period in STAT Mode 5 Min
Pulse Rate Range 40 ~ 240 bpm
Alarm Type SYS DIA MEAN
Measuring and alarm Range
Adult Mode
SYS 40 ~ 270 mmHg
DIA 10 ~ 215 mmHg
MEAN 20 ~ 235 mmHg
Pediatric Mode
SYS 40 ~ 200 mmHg
DIA 10 ~ 150 mmHg
MEAN 20 ~ 165 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Resolution
Pressure 1mmHg
Accuracy
Pressure
Maximum Mean error ±5mmHg
Maximum Standard deviation ±8mmHg
Overpressure Protection
Adult Mode 297±3 mmHg
Pediatric Mode 240±3 mmHg
Neonatal Mode 147±3 mmHg
TEMPERATURE
Channel 2
Measuring and Alarm Range 0 ~ 50 °C
Resolution 0.1°C
Accuracy ±0.1°C
Actualization interval about 1 Sec.
Average Time Constant < 10 Sec.
IBP (optional)
Channel 2
Label ART PA CVP RAP LAP ICP P1 P2
Measuring and alarm range
ART 0~300mmHg
PA -6~120mmHg
CVP/RAP/LAP/ICP -10~40mmHg
P1~P2 -10~300mmHg
Press Sensor
Sensitivity 5 uV/V/mmHg
Impedance 300-3000Ω
Resolution 1mmHg
Accuracy ±2% or 1mmHg which great
Actualization Interval about 1 Sec
Display
Device
12.1 in. Color TFT Made by Sharp Japan
Messages
7 Waveforms Maximum
1 Alarm LED ( Yellow/Red)
1 Power LED (Green)
1 Battery Charge LED ( Yellow)
3 Sound Mode corresponding Alarm Mode
Signal Interface
ECG Output BNC
Amplitude 1 V/mV
Accuracy < 5 %
Impedance 50 Ω
Signal Delay < 20 mS
Recall
Trend Recall
Short 1 hrs 1 Second Resolution
Long 72 hrs 1 Min. Resolution
Alarm Event Recall
71 alarm events of all parameters and 8/16/32seconds of corresponding waveform.
NIBP Measurement Recall
At least 400 NIBP measurement data.
Battery
Rechargeable 3.7 A/Hr 7.4V Li battery
Operating time under the normal use and full charge greater than 180minutes
Operating time after the first alarm of low battery will be about 5 minutes
Recorder (Option)
Record Width 48 mm
Paper Speed 25/50 mm/S
Trace 2
Size and Weight
Size Monitor 310 x 140 x 263 mm
Weight Monitor 3.8 kg
Related Accessories
Standard:
ECG Cable (5 Leads) ...... 1Pcs
SpO2 Cable (Adult) ........ 1Pcs
TEMP Probe (Adult) ....... 1Pcs
NIBP Cuff (Adult) ............ 1Pcs
NIBP Tube(150cm) ......... 1PcsGround Cable ................ 1Pcs
Power Cable ................... 1Pcs
Cleaning Cloth ................ 1Pcs
Options:
ECG Cable (3 Leads)
ECG Alligator Clips (metal)
SpO2 Cable (Adult hard shell sensor)
SpO2 Cable (Adult Soft shell sensor)
SpO2 Cable (Neonatal soft sensor)
NIBP Cuff (infant 8 - 14 cm 5/Bag)ECG Alligator Clips (me
SpO2 Cable (Adult hard shell sensor)
SpO2 Cable (Adult Soft shell sensor)
SpO2 Cable (Neonatal soft sensor)
SpO2 Cable (Pediatric hard shell sensor)
SpO2 Cable (Pediatric Soft shell sensor)
SpO2 Cable (Pediatric Soft shell sensor)
SpO2 Cable (Child finger clip)
SpO2 Cable (multi-site Y type)
SpO2 External Cable
NIBP Cuff (Child 13 - 20 cm 5/Bag)
NIBP Cuff (Small Adult 18 - 26 cm 5/Bag)
NIBP Cuff (Adult 26 - 35 cm 5/Bag)
NIBP Cuff (Adult Long 29 - 38 cm 5/Bag)
NIBP Cuff (Large Adult 32 - 42 cm 5/Bag)
NIBP Cuff (Large Adult Long 35 - 44 cm 5/Bag)
NIBP Cuff (Thigh 42 - 50 cm)
NIBP Tube 150cm
NIBP Tube 150cm
Paper Role
Thermal printer
Patient Monitor Wall mounts (3 Models)
Patient Monitor Trolley (5 Models)
IBP Reusable Interface Cable
IBP Disposable Transducers
Thermal printer
Patient Monitor Wall mounts (3 Models)
Patient Monitor Trolley (5 Models)
EtCO2 Module
Water-trap Column
Airway Adapter
IBP Adapter (2-IBP)
CO2 Sample Line
Nasal TubeWater-trap Column
Airway Adapter
IBP Reusable Interface Cable
IBP Disposable Transducers